Key points Download PDF
Current, p.d. and resistance
- Current I = Q/t (ampere). Potential difference V = W/Q (volt). Resistance R = V/I (ohm).
- Ohm's law: V ∝ I at constant temperature. Ohmic conductors give a straight-line V–I graph through the origin; non-ohmic ones (e.g. diode, filament bulb) don't.
- R depends on length (∝ L), area (∝ 1/A), material (resistivity ρ) and temperature: R = ρL/A.
e.m.f. and internal resistance
- e.m.f. (ε): work done per unit charge by the cell in moving charge round the whole circuit.
- Every cell has an internal resistance r.
- ε = I(R + r) and terminal voltage V = IR = ε − Ir. On open circuit (I = 0), V = ε.
Combination of resistors
- Series: R = R₁ + R₂ + … (same current). Parallel: 1/R = 1/R₁ + 1/R₂ + … (same p.d.).
- n equal resistors R in parallel → R/n; in series → nR.
Electrical energy and power
- W = VIt = I²Rt = V²t/R. P = VI = I²R = V²/R.
- Commercial unit: 1 kWh = 3.6 × 10⁶ J.
- Power rating "100 W – 220 V" means the bulb uses 100 J each second when connected to 220 V. Its resistance R = V²/P = 484 Ω.
Original notes by Allinone Study Point, aligned to the official syllabus.